Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Color Compatibility of Gingival Shade Guides and Gingiva-Colored Dental Materials with Healthy Human Gingiva
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 38 , Issue 3
May/June 2018

Pages 397–403


Color Compatibility of Gingival Shade Guides and Gingiva-Colored Dental Materials with Healthy Human Gingiva

Nima D. Sarmast, DDS, MS, MPH/Nikola Angelov, DDS, MS, PhD/Razvan Ghinea, PhD/John M. Powers, PhD/Rade D. Paravina, DDS, MS, PhD


PMID: 29641629
DOI: 10.11607/prd.3430

The CIELab and CIEDE2000 coverage error (ΔE*COV and ΔE’COV, respectively) of basic shades of different gingival shade guides and gingiva-colored restorative dental materials (n = 5) was calculated as compared to a previously compiled database on healthy human gingiva. Data were analyzed using analysis of variance with Tukey-Kramer multiple-comparison test (P < .05). A 50:50% acceptability threshold of 4.6 for ΔE* and 4.1 for ΔE’ was used to interpret the results. ΔE*COV /ΔE’COV ranged from 4.4/3.5 to 8.6/6.9. The majority of gingival shade guides and gingiva-colored restorative materials exhibited statistically significant coverage errors above the 50:50% acceptability threshold and uneven shade distribution.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help